Skip to content

World Class Water 1050LL Water Softener

Sold out
£0.00

Notify me when back in stock

Fast, Free Shipping
friendly expert support
Advice Before & After Sale
manufacturers warranty
World Class Water 1050LL

Automatic Water Softening for Everyday Whole-Home Protection

A metered domestic water softener designed to reduce hardness minerals before they can form stubborn limescale around your home.

  • Automatic metered operation
  • High-flow stainless steel connection hoses included
  • Suitable for common UK domestic plumbing systems when correctly specified
  • 24-month manufacturer warranty, subject to registration and conditions
World Class Water 1050LL residential water softener

Metered Operation

The electronic controller is programmed to your incoming water hardness and manages regeneration automatically.

Whole-Home Protection

Helps reduce scale formation on showers, taps and surfaces while protecting plumbing and water-using appliances.

Installation Components

Supplied with high-flow stainless steel hoses plus drain and overflow hose components for installation.

Manufacturer Warranty

World Class Water provides a 24-month warranty for manufacturing faults, subject to registration and warranty terms.

World Class Water residential cabinet water softener
Hard Water Protection

Reduce Limescale at the Source

Hard water contains dissolved calcium and magnesium. A salt-based softener removes these hardness minerals before the water circulates around the home, helping prevent new scale deposits from forming.

  • Helps keep shower screens, taps and tiles cleaner
  • Reduces scale reaching boilers and hot-water equipment
  • Helps protect washing machines, dishwashers and kettles
  • Allows soaps and detergents to work more effectively
Automatic Control

Set the Water Hardness, Then Let the Controller Manage Regeneration

The World Class Water controller allows the installer to set the time, regeneration time and incoming water hardness. The display then shows the current time and the volume of softened water remaining.

MeteredAutomatic softener control
2amDefault regeneration time
300 PPMDefault hardness setting
7 DaysRecommended regeneration override setting

Designed Around Your Water Supply

The incoming hardness setting should be adjusted to match the local water supply rather than simply left at the factory default.

For accurate setup, check your local water hardness or test the incoming mains before commissioning the softener.

What's Included

Core Installation Components Supplied

The manufacturer's installation guide lists the main connection components supplied with the softener. Site-specific plumbing fittings may still be required.

  • World Class Water metered cold-water softener
  • Salt lid
  • 2 × high-flow stainless steel hoses
  • Drain hose
  • Half-inch overflow hose
  • Outlet hose mesh washer insert
Important installation note: The manufacturer's guide states that a bypass should be fitted and supplied by the installer. An air-gap fitting is also not supplied with the softener.
Installation Planning

Suitable for Common UK Domestic Plumbing Systems

World Class Water's installation guidance covers mains-pressure systems, combination boilers, unvented hot-water cylinders and gravity-fed systems. Correct positioning and hose selection are important for maintaining reliable flow.

Mains Pressure

Typically installed on the incoming mains after the internal stop valve, with an untreated drinking-water take-off fitted before the softener where required.

Combination Boilers

The guidance recommends large-bore braided hoses to help preserve the flow rates required by combination boiler systems.

Unvented Cylinders

The softener can be installed upstream of an unvented cylinder, with suitable large-bore connections used to support mains-pressure flow.

Gravity-Fed Systems

Installation is also possible on older systems incorporating a cold-water storage tank, subject to the property's plumbing arrangement.

Before Installation

Key Installation Requirements

1.5 barMinimum incoming pressure stated in the guide
PRVManufacturer guidance calls for pressure reduction where site pressure is over 3 bar
5–40°CRecommended ambient installation temperature range
IndoorsInstall in a dry, frost-free location on a solid level floor
Domestic softeners require suitable drainage, overflow provision, backflow protection and access for salt filling and servicing. Installation must comply with applicable UK Water Fittings Regulations.
Product Details

World Class Water 1050LL Specifications & Requirements

Product type Metered domestic cold-water softener
Operation Electronic automatic regeneration
Minimum incoming pressure 1.5 bar
Pressure reduction Manufacturer installation guidance requires a pressure reducing valve where site pressure exceeds 3 bar
Installation environment Indoor, dry and frost-free
Ambient temperature 5°C to 40°C
Maximum incoming water temperature 30°C
Salt type Tablet or pebble salt
Included hoses 2 × high-flow stainless steel hoses
Bypass Installer supplied
Warranty 24 months for manufacturing faults, subject to manufacturer terms and registration
Installation and Operation

Official World Class Water Softener Installation Guide

View the manufacturer's guide covering installation requirements, plumbing layouts, controller setup, salt use, commissioning, warranty terms and registration.

Installation guidanceController programmingPlumbing requirementsWarranty and registration
Common Questions

World Class Water 1050LL FAQs

Is the World Class Water 1050LL automatic?

Yes. It is a metered softener with an electronic controller. The installer programs the time, regeneration time and incoming water hardness during commissioning.

What salt should I use?

World Class Water specifies tablet or pebble salt. The manufacturer recommends checking the salt regularly and keeping the level above the water in the cabinet.

Can it be installed with a combi boiler?

Yes. The manufacturer's installation guide includes specific guidance for combination boiler systems and recommends large-bore braided hoses to help maintain good flow.

Can it be used with an unvented hot-water cylinder?

Yes. World Class Water states that an unvented system can be supplied through a softener installed on the incoming mains, with the softener positioned upstream of the cylinder and associated controls.

Does it come with a bypass?

No. The installation guide states that the bypass should be fitted and supplied by the installer.

What incoming pressure does it require?

The manufacturer states a minimum site pressure of 1.5 bar. Its installation guidance also calls for a pressure reducing valve where site pressure exceeds 3 bar.

Does the softener need electricity?

Yes. The installation diagram specifies a nearby 13A electrical supply for the electronic controller.

How do I protect the warranty?

Follow the manufacturer's installation requirements and complete the softener registration within 21 days of purchase. The handbook lists additional warranty conditions and exclusions.

Need Help Choosing the Right Water Softener?

Not sure whether the World Class Water 1050LL is the right softener for your home? Our technical team can help you assess your water hardness, plumbing system and installation requirements before you order.

Contact Support Team